Mitsubishi Heavy Industries FDTC50VH 5.0kW Compact Ceiling Cassette (FDTC Series)
Mitsubishi Heavy Industries FDTC50VH 5.0kW Compact Ceiling Cassette (FDTC Series) - Honeycomb is backordered and will ship as soon as it is back in stock.
Pickup available at HVACZone
Usually ready in 24 hours
Local Pickup Available
Local Pickup Available
We offer free local pickup from of Clyde North Store
Mitsubishi Heavy Industries FDTC50VH 5.0kW Compact Ceiling Cassette (FDTC Series) - Honeycomb is backordered and will ship as soon as it is back in stock.
Description
Description
The FDTC50VH 5.0kW Compact Ceiling Cassette from Mitsubishi Heavy Industries offers an efficient and versatile solution for commercial spaces requiring high performance in a compact design. With a height of only 258mm, it is one of the most space-saving ceiling cassettes on the market, allowing installation in areas with limited roof clearance.
Equipped with Draught Control Technology, the FDTC series ensures consistent, comfortable airflow while preventing cold drafts. Optional motion sensor technology optimises energy use by detecting room occupancy and switching to energy-saving mode during periods of low activity. The unit also features a built-in 600mm drain pump for flexible installation and is compatible with fascia panels in honeycomb or grid design, offering both functional and aesthetic options.
Key Features:
- Compact design for minimal ceiling space
- Draught Control Technology for efficient airflow and comfort
- Optional motion sensor for energy-saving operation
- Various timer functions for convenient scheduling
- Built-in 600mm drain pump for flexible installation
- Fascia panels available in honeycomb and grid designs
Specifications:
- Power Supply: Single Phase
- Capacity: 5.0kW Cooling / 5.0kW Heating
- Available in: Reverse Cycle
| CAPACITY | 5.0kW | |||
| Set | FDTC50ZSXAWVH | |||
| Indoor | FDTC50VH | |||
| Outdoor | SRC50ZSXA-W | |||
| Power Source (Outdoor Unit) | 1 Phase 240V 50Hz | |||
|
*Operation Data
|
Nominal Capacity (Range)
|
Cooling T1 |
kW
|
5.0 (1.1 -5.6) |
| Heating H1 | 5.4 (0.6-6.3) | |||
| Heating H2 | 4.8 | |||
|
Power Consumption
|
Cooling T1 | 1.4 | ||
| Heating H1 | 1.53 | |||
| Maximum Power Consumption | 2.9 | |||
|
Running Current
|
Cooling T1 |
A
|
6.2 | |
| Heating H1 | 6.7 | |||
| Inrush Current, Maximum Current | 5, 15 | |||
| EER | Cooling T1 | 3.58 | ||
| COP | Heating H1 | 3.53 | ||
| Sound Power Level (JIS C9612) | Outdoor |
dB(A)
|
63 | |
|
Sound Pressure Level (JIS C9612)
|
Indoor | P-Hi:44 Hi:40 Me:35 Lo:27 | ||
| Outdoor | 52 | |||
|
External dimensions (HXWXD)
|
Indoor |
mm
|
248x570x570 | |
| Panel | 10X620X620 TC-PSAE-5AW-E (Honeycomb) / TC-PSAGE-5AW-E (Grid) | |||
| Outdoor | 640×800(+71)x290 | |||
|
Net weight
|
Indoor |
kg
|
Unit 14 Panel 2.5 | |
| Outdoor | 45 | |||
|
Airflow
|
Cooling (Indoor) |
l/s
|
P-Hi: 217 Hi: 183 Me: 150 Lo: 117
|
|
| Heating (Indoor) | ||||
|
Installation Data
|
Refrigerant (R32)
|
Quantity | kg | 1.3 |
| Pre-Charged to Pipe | m | 15 | ||
|
Refrigerant Piping
|
Liquid Line |
mm
|
Ø6.35 | |
| Gas Line | Ø12.7 | |||
| Connection Method | Flare Connection | |||
| Maximum Pipe Length (One Way) |
m
|
30 | ||
| Max Vertical Height Diff. Between O.U. and I.U. | 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) | |||
| Controller | RC-E5, RC-EXZ3A, RCH-E3 or RCN-TC-5AW-E2 / RCN-TC-5AW-E3 (Fine Snow) | |||
| Motion Sensor (Optional) | LB-TC-5W-E | |||
| Demand Response (AS4755) | Yes | |||
|
Outdoor air temperature (upper, lower limits)
|
Cooling |
oC
|
-15 to 46 | |
| Heating | -20 to 20 | |||
• Sound level the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.