Mitsubishi Heavy Industries Bronte® Series DXK24ZRA-WF1 7.1kW Split System
Mitsubishi Heavy Industries Bronte® Series DXK24ZRA-WF1 7.1kW Split System is backordered and will ship as soon as it is back in stock.
Pickup available at HVACZone
Usually ready in 24 hours
Local Pickup Available
Local Pickup Available
We offer free local pickup from of Clyde North Store
Mitsubishi Heavy Industries Bronte® Series DXK24ZRA-WF1 7.1kW Split System is backordered and will ship as soon as it is back in stock.
Description
Description
The Bronte® DXK24ZRA-WF1 7.1kW Split System delivers powerful cooling and heating for large spaces with Jet Air Technology, providing long-reach airflow up to 18 meters in cooling mode. Ideal for open-plan living areas, offices, or larger rooms, this system ensures consistent comfort across the entire space.
With the WF1 range, you can easily control your Bronte® remotely via the MHIAA app, and it also supports voice control with Google Assistant or Amazon Alexa (devices sold separately). The built-in NOVAShield™ PM2.5 filter and Clean Air Technology capture and neutralise allergens, odours, bacteria, and viruses, providing superior indoor air quality.
Key Features:
- Jet Air Technology for long-reach, even airflow in 7.1–9.5kW models
- Clean Air Technology to neutralise allergens, odours, bacteria & viruses
- Wide range of timer and scheduling functions for convenience
- Built-in Wi-Fi and voice control via Google or Alexa (devices sold separately)
- Recognised by ProductReview as one of the best split systems for three consecutive years
| Indoor | DXK24ZRA-WF1 | ||||
| Outdoor | DXC24ZRA-W | ||||
| Power source (Outdoor Unit) | 1 Phase 240V 50Hz | ||||
|
*Operation data
|
Nominal Capacity (Range)
|
Cooling T1 |
kW
|
7.1 (2.3~8.3) | |
| Heating H1 | 8.0 (2.0~10.9) | ||||
| Heating H2 | 8.1 | ||||
|
Power consumption
|
Cooling T1 |
kW
|
1.84 (0.48~2.4) | ||
| Heating H1 | 2.02 (0.4~3.4) | ||||
| Maximum power consumption | kW | 3.65 | |||
|
Running current
|
Cooling T1 |
A
|
7.8 | ||
| Heating H1 | 8.6 | ||||
| Inrush current, maximum current | A | 8.6, 17.0 | |||
| EER | Cooling T1 |
|
3.86 | ||
| COP | Heating H1 | 3.96 | |||
| Sound power level (JIS C9612) | Outdoor | dB(A) | 65 | ||
|
Sound pressure level (JIS C9612)
|
Indoor |
dB(A)
|
43-40-36-24 | ||
| Outdoor | 53 | ||||
|
Energy label (GEMS 2019)
|
HOT
|
Cooling |
|
4 | |
| Heating | 3 | ||||
|
AVERAGE
|
Cooling | 3.5 | |||
| Heating | 2.5 | ||||
|
COLD
|
Cooling | 3.5 | |||
| Heating | 2 | ||||
|
External dimensions (HxWxD)
|
Indoor |
mm
|
339x1197x262 | ||
| Outdoor | 750×880(+88)x340 | ||||
|
Net weight
|
Indoor |
kg
|
15.5 | ||
| Outdoor | 58 | ||||
|
Airflow
|
Indoor (Cooling) |
l/s
|
342-310-270-174 | ||
| Indoor (Heating) | 425-330-288-222 | ||||
|
Refrigerant (Type, amount, pre-charge length)
|
Quantity | kg | (R32) 1.6 | ||
| Pre charged to pipe length | m | 15 | |||
|
Installation data
|
Refrigerant piping
|
Liquid line |
mm
|
Ø6.35 | |
| Gas line | Ø15.88 | ||||
| Connection method | Flare connection | ||||
| Maximum pipe (one way) length | m | 30 | |||
| Max vertical height diff. between O.U. and I.U. | m | 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) | |||
| Standard accessories | Allergen clear filter , NOVAShield Nano filter (PM2.5), Built-in Wi-Fi | ||||
| Optional parts | Interface kit (SC-BIKN2-E) | ||||
| Demand response (AS4755) | Yes | ||||