  • Cooling Capacity: 12.5 kW | Heating Capacity: 14 kW
  • High External Static Pressure: Up to 150 Pa for versatile ducting options
  • 2-Piece Construction: Perfect for renovations or homes with limited installation space
  • Flexible Design: Supports optional zoning for targeted comfort control
  • Smart Home Integration: Compatible with home automation systems
  • 4 Fan Speed Settings: Customisable airflow for optimal comfort

Applications

  • Residential ducted air conditioning for single or multi-zone setups
  • Homes undergoing renovation or retrofit installations
  • Ideal for spaces requiring precise temperature control and smart home compatibility

Why Choose This Product?

The PEAMS125HAAV Ducted Kit combines high-capacity heating and cooling, flexible installation, and smart home integration, offering a comfortable, energy-efficient, and modern solution for year-round climate control.

Indoor Unit PEA-M125HAA
Outdoor Unit PUZ-M125VKA-A
Refrigerant R32
Power Supply
Source Outdoor power supply
Outdoor V: 230V, Single-phase, 50Hz
Indoor
Cooling
Capacity [Min-Rated*4-Max] kW 6.00 – 12.00 – 13.50
Total Input [Rated]*4 kW 3.78
AEER/EER*1 3.10/3.17
TCSPF (Residential)
Hot 4.3
Average 3.77
Cold 3.83
Running Current [Rated]*4 A 17.4
Sound Pressure Level*2
In (Lo-Mid2- Mid1-Hi) (SPL) dBA 35 – 38 – 42 – 45
Out (PWL) dBA 54 (72)
Air Volume (In) Lo-Mid2-Mid1-Hi L/s 700 – 800 – 900 –
1000
Heating
Capacity [Min-Rated*5-Max] kW 4.10 – 14.00 – 15.50
Total Input [Rated]*5 kW 3.44
ACOP/COP *1 3.69/4.06
HSPF (Residential)
Hot 4.42
Average 3.87
Cold 3.27
Running current [Rated]*5 A 16
Sound Pressure Level*2
In (Lo-Mid2 Mid1-Hi) (SPL) dBA 35 – 38 – 42 – 45
Out (PWL) dBA 56 (74)
Air Volume (In) Lo-Mid2-Mid1-Hi L/s 700 – 800 – 900 –
1000
Max. Running Current A 30.2
Indoor Unit
Input [Rated] kW 0.477/0.477
Dimensions [HxWxD] mm 380 x 1405 x 900
Weight kg 66
Static Pressure Pa 50/100/150
Outdoor Unit
Dimensions [HxWxD] mm 981 x 1050 x 330
(+40)
Weight kg 84
Breaker Size A 32
Ext.Piping
Diameter [Liquid/Gas] mm ø9.52/ø15.88
Max. Length/Height m 55/30
Guaranteed Operating Range [Outdoor]
Cooling*3 °C -15 ~ 46
Heating °C -15 ~ 21
Supply Air Duct mm 1325 x 266
Return Air Duct mm 2 x 400 (2 x 16”)
Pre-Charge Refrigerant kg 3.60 (30m)
Additional Refrigerant g/m 40