Mitsubishi Electric PEAMS140HAAV Ducted Air Conditioner – 14 kW
Mitsubishi Electric PEAMS140HAAV Ducted Air Conditioner – 14 kW is backordered and will ship as soon as it is back in stock.
Pickup available at HVACZone
Usually ready in 24 hours
Local Pickup Available
Local Pickup Available
We offer free local pickup from of Clyde North Store
Mitsubishi Electric PEAMS140HAAV Ducted Air Conditioner – 14 kW is backordered and will ship as soon as it is back in stock.
Description
Description
Enjoy year-round comfort and precise climate control with the Mitsubishi Electric PEA-M140HAAV Ducted Kit. With its 2-piece design, optional zoning, and smart home integration, this high-capacity ducted system is perfect for home renovations or new installations, offering flexibility, efficiency, and convenience.
Key Features
- Cooling Capacity: 14.0 kW | Heating Capacity: 16.0 kW
- High External Static Pressure: Up to 150 Pa for versatile ducting options
- 2-Piece Construction: Ideal for renovations and homes with restricted installation space
- Flexible Design: Supports optional zoning for targeted comfort
- Smart Home Integration: Compatible with home automation systems
- 4 Fan Speed Settings: Customisable airflow for optimal comfort
Applications
- Residential ducted air conditioning for single or multi-zone setups
- Homes undergoing renovation or retrofit installations
- Spaces requiring precise temperature control and smart home compatibility
Why Choose This Product?
The PEA-M140HAAV Ducted Kit combines high-capacity heating and cooling, flexible installation, and smart home integration, providing an energy-efficient and modern solution for year-round home comfort.
| Indoor Unit | PEA-M140HAA | |||
| Outdoor Unit | PUZ-M140VKA-A | |||
| Refrigerant | R32 | |||
|
Power Supply
|
Source | Outdoor power supply | ||
| Outdoor | V: 230 V, Single-phase, 50 Hz | |||
| Indoor | – | |||
|
Cooling
|
Capacity [Min-Rated*4-Max] | kW | 6.20 – 14.00 – 15.30 | |
| Total Input [Rated]*4 | kW | 4.24 | ||
| AEER/EER*1 | 3.23/3.30 | |||
|
TCSPF (Residential)
|
Hot | 4.49 | ||
| Average | 3.98 | |||
| Cold | 4.06 | |||
| Running Current [Rated]*4 | A | 19.5 | ||
|
Sound Pressure Level*2
|
In (Lo-Mid2- Mid1-Hi) (SPL) | dBA | 35 – 38 – 42 – 45 | |
| Out (PWL) | dBA | 53 (71) | ||
| Air Volume (In) Lo-Mid2-Mid1-Hi | L/s | 700 – 800 – 900 – 1000 | ||
|
Heating
|
Capacity [Min-Rated*5-Max] | kW | 5.70 – 16.00 – 18.00 | |
| Total Input [Rated]*5 | kW | 3.85 | ||
| ACOP/COP | 4.06/4.15 | |||
|
HSPF (Residential)
|
Hot | 4.69 | ||
| Average | 4.2 | |||
| Cold | 3.6 | |||
| Running current [Rated]*5 | A | 17.7 | ||
|
Sound Pressure Level*2
|
In (Lo-Mid2 Mid1-Hi) (SPL) | dBA | 35 – 38 – 42 – 45 | |
| Out (PWL) | dBA | 54 (72) | ||
| Air Volume (In) Lo-Mid2-Mid1-Hi | L/s | 700 – 800 – 900 – 1000 | ||
| Max. Running Current | A | 30.2 | ||
|
Indoor Unit
|
Input [Rated] | kW | 0.477/0.477 | |
| Dimensions [HxWxD] | mm | 380 x 1405 x 900 | ||
| Weight | kg | 66 | ||
| Static Pressure | Pa | 50/100/150 | ||
|
Outdoor Unit
|
Dimensions [HxWxD] | mm | 1338 x 1050 x 330 (+40) | |
| Weight | kg | 99 | ||
| Breaker Size | A | 40 | ||
|
Ext.Piping
|
Diameter [Liquid/Gas] | mm | ø9.52/ø15.88 | |
| Max. Length/Height | m | 55/30 | ||
|
Guaranteed Operating Range [Outdoor]
|
Cooling*3 | °C | -5(-15) ~ 46 | |
| Heating | °C | -15 ~ 21 | ||
| Supply Air Duct | mm | 1325 x 266 | ||
| Return Air Duct | mm | 2 x 400 (2 x 16”) | ||
| Pre-Charge Refrigerant | kg | 4.00 (55m) | ||
| Additional Refrigerant | g/m | Not required | ||