{"product_id":"mitsubishi-heavy-industries-multi-split-system-scm40zs-w-4-0kw-outdoor-unit","title":"Mitsubishi Heavy Industries Multi Split System SCM40ZS-W 4.0KW 2 Port (Outdoor Unit)","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMitsubishi Heavy Industries SCM40ZS-W 4.0kW Outdoor Multi Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith the ability to connect 2 indoor units to a single outdoor unit, the SCM40ZS-W outdoor multi-split system offers a compact and versatile solution for cooling and heating multiple rooms. Thanks to improved component design, the SCM-ZS-W series boasts super quiet operation while also delivering high energy efferences. The ability to control each indoor unit independently offers even further energy savings while also providing complete control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"h3\"\u003eKey features\u003c\/h2\u003e\n\u003cul class=\"key-features\"\u003e\n\u003cli class=\"key-features__item\"\u003eIndividual control over each room\u003c\/li\u003e\n\u003cli class=\"key-features__item\"\u003eEnergy efficient solution for multiple rooms\u003c\/li\u003e\n\u003cli class=\"key-features__item\"\u003eWide range of indoor units to suit any space\u003c\/li\u003e\n\u003cli class=\"key-features__item\"\u003eSuper quiet operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eOutdoor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSCM40ZS-W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003ePower source (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e1 Phase 240V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"15\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e*Operation data\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNominal Capacity (Range)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling T1\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ekW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4.0 (1.5~5.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating H1\u003c\/td\u003e\n\u003ctd\u003e4.5 (1.0~6.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePower consumption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling T1\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating H1\u003c\/td\u003e\n\u003ctd\u003e0.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eRunning current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling T1\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating H1\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInrush current, maximum current\u003c\/td\u003e\n\u003ctd\u003e3.7, 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER\u003c\/td\u003e\n\u003ctd\u003eCooling T1\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd\u003e5.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003eHeating H1\u003c\/td\u003e\n\u003ctd\u003e5.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSound power level (JIS C9612)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling T1\u003c\/td\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003edB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating H1\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSound pressure level (JIS C9612)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling T1\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating H1\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSilent mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling T1\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating H1\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eExternal dimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e595×780(+90)x290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eNet weight\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ekg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eRefrigerant (R32)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre charged to pipe length\u003c\/td\u003e\n\u003ctd\u003em\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation data\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eRefrigerant piping\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eLiquid line\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003emm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eØ6.35 x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas line\u003c\/td\u003e\n\u003ctd\u003eØ9.52 x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eConnection method\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlare connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaximum pipe length to one indoor unit\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003em\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTotal pipe length to all indoor units\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMax vertical height diff. between O.U. and I.U.\u003c\/td\u003e\n\u003ctd\u003e15 ( O.U. above I.U.) \/ 15 ( O.U. below I.U. )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"7\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndoor Unit Combination\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSRK-ZSA-W\u003c\/td\u003e\n\u003ctd rowspan=\"7\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ekW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.0, 2.5, 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRK-ZSXA-W\u003c\/td\u003e\n\u003ctd\u003e2.0, 2.5, 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRK-ZRA-W\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRF-ZS(X)-W\u003c\/td\u003e\n\u003ctd\u003e2.5, 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRR-ZS-W\u003c\/td\u003e\n\u003ctd\u003e2.5, 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFDTC-VH\u003c\/td\u003e\n\u003ctd\u003e2.5, 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFDUM-VH\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eIndoor Unit Connection\u003c\/td\u003e\n\u003ctd\u003e2 Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eIndoor Connection Capacity\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e4.0 to 6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eOutdoor air temperature (upper, lower limits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e°C\u003c\/td\u003e\n\u003ctd\u003e-15 to 46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating\u003c\/td\u003e\n\u003ctd\u003e-15 to 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e* Operation data are are conducted in accordance with AS\/NZS 3823 standard. For testing conditions please refer to Page14.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Mitsubishi Heavy Industries","offers":[{"title":"Default Title","offer_id":48938131914992,"sku":"1187","price":1409.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0804\/7886\/3600\/files\/Mitsubishi-SRC_Multi_outdoor.jpg?v=1774301323","url":"https:\/\/hvaczone.com.au\/products\/mitsubishi-heavy-industries-multi-split-system-scm40zs-w-4-0kw-outdoor-unit","provider":"HVAC Zone","version":"1.0","type":"link"}