{"product_id":"mitsubishi-electric-pea-m140haav-14kw-ducted-kit","title":"Mitsubishi Electric PEAMS140HAAV Ducted Air Conditioner – 14 kW","description":"\u003cp data-start=\"71\" data-end=\"407\"\u003eEnjoy \u003cstrong data-start=\"77\" data-end=\"127\"\u003eyear-round comfort and precise climate control\u003c\/strong\u003e with the \u003cstrong data-start=\"137\" data-end=\"184\"\u003eMitsubishi Electric PEA-M140HAAV Ducted Kit\u003c\/strong\u003e. With its \u003cstrong data-start=\"195\" data-end=\"213\"\u003e2-piece design\u003c\/strong\u003e, optional zoning, and \u003cstrong data-start=\"236\" data-end=\"262\"\u003esmart home integration\u003c\/strong\u003e, this high-capacity ducted system is perfect for \u003cstrong data-start=\"312\" data-end=\"353\"\u003ehome renovations or new installations\u003c\/strong\u003e, offering flexibility, efficiency, and convenience.\u003c\/p\u003e\n\u003chr data-start=\"409\" data-end=\"412\"\u003e\n\u003ch3 data-start=\"414\" data-end=\"434\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"418\" data-end=\"434\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"435\" data-end=\"893\"\u003e\n\u003cli data-start=\"435\" data-end=\"500\"\u003e\n\u003cstrong data-start=\"437\" data-end=\"458\"\u003eCooling Capacity:\u003c\/strong\u003e 14.0 kW | \u003cstrong data-start=\"469\" data-end=\"490\"\u003eHeating Capacity:\u003c\/strong\u003e 16.0 kW\u003c\/li\u003e\n\u003cli data-start=\"501\" data-end=\"582\"\u003e\n\u003cstrong data-start=\"503\" data-end=\"537\"\u003eHigh External Static Pressure:\u003c\/strong\u003e Up to 150 Pa for versatile ducting options\u003c\/li\u003e\n\u003cli data-start=\"583\" data-end=\"679\"\u003e\n\u003cstrong data-start=\"585\" data-end=\"610\"\u003e2-Piece Construction:\u003c\/strong\u003e Ideal for renovations and homes with restricted installation space\u003c\/li\u003e\n\u003cli data-start=\"680\" data-end=\"750\"\u003e\n\u003cstrong data-start=\"682\" data-end=\"702\"\u003eFlexible Design:\u003c\/strong\u003e Supports optional zoning for targeted comfort\u003c\/li\u003e\n\u003cli data-start=\"751\" data-end=\"822\"\u003e\n\u003cstrong data-start=\"753\" data-end=\"780\"\u003eSmart Home Integration:\u003c\/strong\u003e Compatible with home automation systems\u003c\/li\u003e\n\u003cli data-start=\"823\" data-end=\"893\"\u003e\n\u003cstrong data-start=\"825\" data-end=\"850\"\u003e4 Fan Speed Settings:\u003c\/strong\u003e Customisable airflow for optimal comfort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"895\" data-end=\"898\"\u003e\n\u003ch3 data-start=\"900\" data-end=\"920\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"904\" data-end=\"920\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"921\" data-end=\"1128\"\u003e\n\u003cli data-start=\"921\" data-end=\"992\"\u003eResidential ducted air conditioning for single or multi-zone setups\u003c\/li\u003e\n\u003cli data-start=\"993\" data-end=\"1050\"\u003eHomes undergoing renovation or retrofit installations\u003c\/li\u003e\n\u003cli data-start=\"1051\" data-end=\"1128\"\u003eSpaces requiring precise temperature control and smart home compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1130\" data-end=\"1133\"\u003e\n\u003ch3 data-start=\"1135\" data-end=\"1167\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1139\" data-end=\"1167\"\u003eWhy Choose This Product?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1168\" data-end=\"1383\"\u003eThe \u003cstrong data-start=\"1172\" data-end=\"1199\"\u003ePEA-M140HAAV Ducted Kit\u003c\/strong\u003e combines \u003cstrong data-start=\"1209\" data-end=\"1297\"\u003ehigh-capacity heating and cooling, flexible installation, and smart home integration\u003c\/strong\u003e, providing an \u003cstrong data-start=\"1312\" data-end=\"1380\"\u003eenergy-efficient and modern solution for year-round home comfort\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"100\"\u003e \u003ccol width=\"100\"\u003e \u003ccol width=\"100\"\u003e \u003ccol width=\"100\"\u003e \u003ccol width=\"100\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003eIndoor Unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePEA-M140HAA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003eOutdoor Unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePUZ-M140VKA-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003e\n\u003cdiv\u003ePower Supply\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eSource\u003c\/td\u003e\n\u003ctd\u003eOutdoor power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eOutdoor\u003c\/td\u003e\n\u003ctd\u003eV: 230 V, Single-phase, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eIndoor\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"10\"\u003e\n\u003cdiv\u003eCooling\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eCapacity [Min-Rated*4-Max]\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e6.20 – 14.00 – 15.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eTotal Input [Rated]*4\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e4.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eAEER\/EER*1\u003c\/td\u003e\n\u003ctd\u003e3.23\/3.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"3\"\u003e\n\u003cdiv\u003eTCSPF (Residential)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eHot\u003c\/td\u003e\n\u003ctd\u003e4.49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage\u003c\/td\u003e\n\u003ctd\u003e3.98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold\u003c\/td\u003e\n\u003ctd\u003e4.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eRunning Current [Rated]*4\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\n\u003cdiv\u003eSound Pressure Level*2\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIn (Lo-Mid2- Mid1-Hi) (SPL)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e35 – 38 – 42 – 45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOut (PWL)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e53 (71)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eAir Volume (In) Lo-Mid2-Mid1-Hi\u003c\/td\u003e\n\u003ctd\u003eL\/s\u003c\/td\u003e\n\u003ctd\u003e700 – 800 – 900 – 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"10\"\u003e\n\u003cdiv\u003eHeating\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eCapacity [Min-Rated*5-Max]\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e5.70 – 16.00 – 18.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eTotal Input [Rated]*5\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e3.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eACOP\/COP\u003c\/td\u003e\n\u003ctd\u003e4.06\/4.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"3\"\u003e\n\u003cdiv\u003eHSPF (Residential)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eHot\u003c\/td\u003e\n\u003ctd\u003e4.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage\u003c\/td\u003e\n\u003ctd\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold\u003c\/td\u003e\n\u003ctd\u003e3.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eRunning current [Rated]*5\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e17.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\n\u003cdiv\u003eSound Pressure Level*2\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIn (Lo-Mid2 Mid1-Hi) (SPL)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e35 – 38 – 42 – 45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOut (PWL)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e54 (72)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eAir Volume (In) Lo-Mid2-Mid1-Hi\u003c\/td\u003e\n\u003ctd\u003eL\/s\u003c\/td\u003e\n\u003ctd\u003e700 – 800 – 900 – 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eMax. Running Current\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e30.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003e\n\u003cdiv\u003eIndoor Unit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eInput [Rated]\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e0.477\/0.477\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eDimensions [HxWxD]\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e380 x 1405 x 900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eStatic Pressure\u003c\/td\u003e\n\u003ctd\u003ePa\u003c\/td\u003e\n\u003ctd\u003e50\/100\/150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003e\n\u003cdiv\u003eOutdoor Unit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eDimensions [HxWxD]\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e1338 x 1050 x 330 (+40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eBreaker Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\n\u003cdiv\u003eExt.Piping\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eDiameter [Liquid\/Gas]\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003eø9.52\/ø15.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eMax. Length\/Height\u003c\/td\u003e\n\u003ctd\u003em\u003c\/td\u003e\n\u003ctd\u003e55\/30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\n\u003cdiv\u003eGuaranteed Operating Range [Outdoor]\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling*3\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e-5(-15) ~ 46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e-15 ~ 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eSupply Air Duct\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e1325 x 266\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eReturn Air Duct\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e2 x 400 (2 x 16”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003ePre-Charge Refrigerant\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003ctd\u003e4.00 (55m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eAdditional Refrigerant\u003c\/td\u003e\n\u003ctd\u003eg\/m\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":48898636054768,"sku":"1515","price":4940.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0804\/7886\/3600\/files\/MITSUBISHI-ELECTRIC-PEA-M140HAA-14.0-kW-Ducted-Air-Conditioner-System-1-Phase-wired-controller.png?v=1774313882","url":"https:\/\/hvaczone.com.au\/products\/mitsubishi-electric-pea-m140haav-14kw-ducted-kit","provider":"HVAC Zone","version":"1.0","type":"link"}